Vitenskapelig artikkel

Rapid determination of internal properties of plums with a commercial multi-parameter electrode system

Haugen, John-Erik; Lundby, Frank; Bengtsson, Gunnar

Publikasjonsdetaljer

Tidsskrift: Acta Horticulturae, vol. 604, p. 585–590, 2003

Internasjonale standardnumre:
Trykt: 0567-7572

Open Access: none

A feasibility study has been carried out to evaluate the potential of a commercial multi-parameter electrode system for rapid determination of quality related parameters in fruit juice. The electrode system used was an ISFET based electrode for measurements of pH, temperature, conductivity, salinity, total dissolved solids, redox potential and relative potential. The electrode readings were used as inputs to multivariate regression modelling for prediction of reference quality related parameters determined with conventional methods. Highest correlation was obtained for titratable acidity (r = 0.89), and the ratios soluble solids/titratable acidity (r = 0.81) and total sugars/titratable acidity (r = 0.78) with prediction error from 9 to 14%. This suggests that commercial multi-parameter electrodes based on ISFET technology may be applied to perform simple and rapid indirect determination of fruit parameters related to quality.